Hollis 150LX DC7 Regulator Yoke

SKU: HLS1D2Y MFR: 240.1504.07.M

Key Features

  • Experience reliable, balanced regulator performance with the Hollis DC7 150LX.
  • Enjoy effortless breathing at any depth with this pneumatically balanced 2nd stage.
  • Cold-water rated regulator; dive confidently in even the chilliest conditions.
  • Customize your dive with the adjustable Venturi dive/pre-dive switch feature.
  • This compact scuba regulator features 4 LP and 2 HP ports for versatile setup.
  • Nitrox compatible regulator; safely explore enriched air diving environments.
See More Product Details
Overview
Compare
Specs
Q&A

Questions & Answers

Shopper : Why Did You Choose This?JANAE B : Recommended by friend

Reviews about this item

Review Summary

Hollis 150LX DC7 Regulator Specifications

  • 1'st Stage Type

    Over-Balanced Diaphragm

  • LP Ports

    Four 3/8" Threaded

  • HP Ports

    Two 7/16" Threaded

  • Adjustable 2'nd Stage

    Yes, Venturi Dive/Pre-Dive Switch

  • NITROX Compatible

    Yes

  • 2'nd Stage Type

    Pneumatically Balanced

  • Materials

    First Stage: Forged Marine-Grade Chrome Plated Brass, Second Stage: Housing, ABS/Polycarbonate, Valve Body: Chromed Brass, Cover Ring and Packing Nut: Stainless Steel

  • Hose Thread

    3/8"

  • Hose Length

    30" (76.2 cm)

  • UPC Code

    020545211044

About Hollis 150LX DC7 Regulator

The Hollis 150LX Regulator, a moderately-priced addition to the Hollis line, features a design similar to the 200LX without PVD Plating. Paired with the DC2 DIN or Yoke first stage, it's ideal for global travel or long deco stops. The 150LX includes a stainless steel front ring, packing nut, and end cap, and comes standard with a 30" (76.2 cm) MiFlex hose and an orthodontic mouthpiece with dual color tabs.

The compact Hollis DC2 1st Stage Regulator boasts an over-balanced diaphragm design, providing superior gas delivery under extreme conditions. Its diaphragm membrane prevents contaminants from entering the mechanism, reducing corrosion and performance deterioration. The DC2 also features a secondary diaphragm sealing off the spring chamber, adding another layer of corrosion resistance and preventing first stage icing. The regulator has four LP ports with 3/8" threads and two HP ports with 7/16" threads, is made of forged marine-grade chrome-plated brass, and is Nitrox compatible up to 40% out of the box.

The pneumatically balanced 150XL Second Stage Regulator ensures smooth, easy breathing due to its chrome-plated brass valve. It has a reversible demand valve, allowing for right or left-handed hose configurations, and an adjustable Dive/Pre-Dive switch with a soft rubber grip. The ergonomic design channels bubbles away from the field of view and reduces exhaust effort. The improved orthodontic mouthpiece features dual color tabs and a stainless steel ring. A CD owner's manual is included.

Hollis 150LX DC7 Regulator Features

  • Hollis 150LX DC7 Regulator:
  • Meets Rigorous CE Standard for Coldwater Performance
  • 30" (76.2 cm) 3/8" Threaded Maxflex Hose
  • Lightweight, Flexible, Braided Hose
  • Designed to Outperform and Outlive Traditional Rubber Hoses
  • CD Owner's Manual
  • First-Stage Regulator: Hollis DC2, Yoke
  • Over-Balanced Diaphragm Regulator Design
  • Provides Progressively Greater Intermediate Pressure with Increased Depth and Gas Density
  • Superior Gas Delivery Under Most Extreme Conditions
  • Dual Diaphragm Design: Completely Seals Internal Components from Environment
  • Environmental Sealing Prevents Icing
  • 4 Low Pressure Ports (LP) with 3/8" Threads
  • 2 High Pressure Port (HP) with 7/16" Threads
  • Material: Forged Marine-Grade Chrome Plated Brass
  • Compact & Streamlined Design
  • Ultimate Control Over Internal Air Path for Superior Air Delivery
  • Nitrox Compatible to 40% Out-of-the-Box
  • Weight: 35.2 oz. (998 g)
  • Second Stage Regulator: Hollis 150LX
  • Lightweight ABS/Polycarbonate Housing
  • Pneumatically Balanced Demand Valve Design
  • Chrome-Plated Brass Valve, Stainless Steel Cover Ring & Packing Nut & End Cap
  • Smooth, Easy Breathing
  • Adjustable Venturi System (A.V.S.)
  • AVS: Simple Dive/Pre-Dive Switch Adjust Inhalation Effort
  • AVS: Prevents Free-Flow During Shore Entries or Long Surface Swims
  • Patented Silicone Rubber Orthodontic Mouthpiece
  • Mouthpiece Provides Comfort and Reduced Jaw Fatigue
  • Large Venturi Lever w/Soft Rubber Grip, Easy to Locate and Use
  • Improved Silicone Rubber Orthodontic Mouthpiece w/Dual Color Tabs
  • Ergonomic Exhaust: Channels Bubbles Away from Field of View
  • Exhaust Design: Reduces Exhaust Effort

Warranty Information

This product has a limited warranty of 24 months.

Key Features

  • Experience reliable, balanced regulator performance with the Hollis DC7 150LX.
  • Enjoy effortless breathing at any depth with this pneumatically balanced 2nd stage.
  • Cold-water rated regulator; dive confidently in even the chilliest conditions.
  • Customize your dive with the adjustable Venturi dive/pre-dive switch feature.
  • This compact scuba regulator features 4 LP and 2 HP ports for versatile setup.
  • Nitrox compatible regulator; safely explore enriched air diving environments.

What's in the box:

  • 1'st Stage Regulator
  • 2'nd Stage Regulator
  • Hose
  • CD Owner's Manual